Easy methods to use an oxygen compressor?



Using an oxygen compressor just isn't as complicated as you could possibly think, it's actually simple. After the compressor is installed, it can be place in normal operation after standard test. If you desire to adjust a parameter, you need to follow the steps down below:



1. Pressure switch setpoint shift


The machine usually features 2 pressure switches. Finding the one you might want to adjust not only needs to learn how to use the oxygen compressor, and the maintenance of the actual oxygen compressor, because it is related to normal use. Control basic principle: Loading pressure (starting pressure) + differential strain = stop pressure.



l As soon as adjusting, take the pressure gauge because the standard and loosen this tightening nut;



l Minimize the loading pressure: turn the pressure adjusting screw clockwise (pointer up, pressure decrease) for half seven days, observe whether the loading pressure meets certain requirements (because the pressure difference is just not adjusted, the stopping demand will change accordingly), otherwise, adjust it appropriately.



l Increase the pressure difference: rotate the actual differential pressure adjustment attach counterclockwise (the pointer changes down, the pressure difference increases) for half 7 days, and observe whether the pressure difference could be the stop pressure or not really, if no adjustment is created.



l After each strain value is reset, lock the nut and correct the parameters once. Increase the loading pressure or reduce the pressure difference plus reverse the adjustment because described above. The inlet pressure switch adjustment method is actually the same, but the wiring method takes a different approach, the stop pressure currently = starting pressure - differential pressure. It is strictly forbidden to perform the machine above this rated exhaust pressure.



COUPLE OF. Temperature controller adjustment


Each stage of the compressor gives you a temperature controller, and that is installed on the control cabinet panel and it is set at the manufacturing plant.

Set it, if you should reset, please refer towards the manual of the clever temperature controller.



3. Energy relay regulation


The thermal relay acts as a motor overload protection. Occasionally, the motor will end rotating. If the set value is decided to be malfunctioning, it needs to be properly adjusted by expert electric work, and the running current need to be measured. When the compressor can be working normally, there is less work to be maintained, but it has to be handled by a particular person. It should be patrolled twice per shift to observe whether the compressor possesses abnormal heat, abnormal vibration, abnormal sound, etc. If it is vital, stop it immediately. Immediately after confirming the troubleshooting, you possibly can continue to run. When they get home of each shift, the ability should be turned off along with the intake valve closed. So as to ensure long-term reliable operation in the machine, it must always be checked regularly.



Oxygen compressor regime maintenance and precautions
ONE PARTICULAR. When the compressor is definitely running, it must carefully do necessary inspections and inspections, monitor the operating conditions on the compressor, closely monitor this suction, exhaust pressure as well as temperature, exhaust volume, cooling water temperature along with other control indicators, pay particular attention to abnormal noise, and Record every from time to time.



2. During the functioning, the process gas will be strictly prevented from being crushed in the low-pressure cylinder and other gas pipelines because of the high-pressure cylinder to avert oil, water and water.



3. It is forbidden to control the compressor under over-temperature, over-pressure along with over-speed. If there is any abnormality, you should carefully clear away the fault and report it in time.



4. Gas leakage Once the vehicle is in catastrophe stop, the power ought to be cut off in the particular substation.



5. When repairing the equipment, carefully check the maintenance license as well as the relevant safety inspection regulations to be sure the safety of this inspection.



6. When implementing an oxygen compressor, do not use oily sand to wipe the equipment, pipes, valves and components. Do not be infected by oil. Degreasing treatment really should be carried out after inspection, and flammable gas leakage monitoring equipment need to be provided.



7. Check the machine room and arbitrarily heap flammable materials.



In conclude


You don't have to worry about the caliber of the compressor, because your oxygen compressors, nitrogen compressors, CARBON compressors, etc. have passed the EU CE certification and are also recognized for the safety in the compressor. If you still don't know how to use it, you can certainly consult us. But be sure to pay attention to protection work.